The Reaction Vessel Attenuator Assembly with Resin Loader for HT12/HT24 consists of the Liberty Blue attenuator with a resin tube, communications/power cable for the resin tube motor, tubing, and 30 mL reaction vessel. Saber más
Discover SP-D Fume Cabinet for 24/48 place autosampler. Fume Cabinet designed to be used with the Discover SP-D with Explorer 24/48. Includes retrofit kit PN 730099.
Saber más
Discover SP-D Fume Cabinet for 36/72 place autosampler. Fume Cabinet designed to be used with the Discover SP-D with Explorer 36/72. Includes retrofit kit PN 730099. Saber más
Discover SP-D Fume Cabinet for 48/96 place autosampler. Fume Cabinet designed to be used with the Discover SP-D with Explorer 48/96. Includes retrofit kit PN 730099. Saber más
The Bottle Tubing Bundle for Pass-Through Bottle Caps consists of two tubes use to connect pressure rated bottles to Deprotection and Main Wash positions Saber más
The Discover Spill Tray for Liberty Blue HT12/HT24 is designed to prevent any reagent spills or drips that occur when loading reagents on the system from damaging the Discover microwave reactor. Saber más
TFM spill cup supplied with the Discover SPD 80 reactor. The spill cup inserts directly into cavity to protect the cavity and infrared sensor from damage due to spillage or ruptured reaction vials. Note: Cup Includes side feature for temperature. Compatible with Discover SP-D 80 Plus only
Saber más
Removable spill tank used to capture and contain reaction components and vial fragments should a reaction vial fail in the cavity of the system. These trays fit into the spill channel of the system and are installed with a thumbscrew. Saber más
PTFE Coil to provide a delay time between the detector flow cell and collector valve. Optimized for flow rates of 4-8 mL/min (typical of 10 mm ID columns). Saber más
PTFE Coil to provide a delay time between the detector flow cell and collector valve. Optimized for flow rates of 15-45 mL/min (typical of 20 - 30 mm ID columns). Saber más
This all-in-one-tool contains an iPrep Torque tool assembly featuring 21 inch lbs. of torque for simple one-click assembly and has an attachable removal tool for ease of use during disassembly. Saber más
Calibration tool used to aid in the calibration of the EDGE Extraction Systems autosampler. The the black cap should be inserted into the autosampler fork.
Autosampler for sequential chemical synthesis, requires Discover 2.0 microwave reactor (sold separately). Run up to 12 reactions per queue, a mixture of 10-mL and 35-mL vessels. Saber más
Autosampler for sequential chemical synthesis, requires Discover 2.0 microwave reactor (sold separately). Run up to 48 reactions per queue, a mixture of 10-mL and 35-mL vessels. Saber más
The Resin Distributor kit includes an adaptor block that holds the 96-well synthesis plate, three loading plate options, and a transfer plate that houses the loading plate. Saber más
The Liberty Blue™ HT12 System Upgrade converts a Discover to an automated microwave peptide synthesizer designed for Fmoc solid phase peptide synthesis. Saber más
The Liberty Blue™ HT24 System Upgrade converts a Discover to an automated microwave peptide synthesizer designed for Fmoc solid phase peptide synthesis. Saber más
The 120 mL Amino Acid Bottle is a larger reservoir for use on the Amino Acids on the Liberty Blue and Resin positions on the 12 and 24 position High Throughput modules. Saber más
The Fiber Optic Temperature Probe is 3 ft (91 cm) fiber optic temperature probe with connector for fiber optic temperature measurement and control option. Saber más
Consists of 1x 35 mL attenuator with hole for probe, 1x 10 mL attenuator with hole for probe, 1 open vessel attenuator, 1x 35 mL vessel with integrated thermowell , 1x 10 mL vessel with integrated thermowell, fiber optic option. Saber más
This is a direct replacement for the thermoplastic autosampler racks included with the Explorer 24. This part allows for the insertion of the internal stirring mechanism to effect enhanced stirring with solid supports and highly viscous reaction mixtures. Saber más
Consists of 1x 80 mL attenuator with hole for probe, 1 open vessel attenuator, 1x 80 mL vessel with integrated thermowell, fiber optic option. Saber más
The easiest to assemble vessel for digestion or extraction of plants, vitamins, foods, and many environmental samples with 50 mL measurement line for easy dilutions. Saber más
The easiest to assemble vessel for digestion or extraction of plants, vitamins, foods, and many environmental samples with 50 mL measurement line for easy dilutions.
Saber más
The easiest to assemble vessel for digestion or extraction of plants, vitamins, foods, and many environmental samples with 50 mL measurement line for easy dilutions. Saber más
The easiest to assemble vessel for digestion or extraction of plants, vitamins, foods, and many environmental samples with 50 mL measurement line for easy dilutions.
Saber más
The easiest to assemble vessel for digestion or extraction of plants, vitamins, foods, and many environmental samples with 50 mL measurement line for easy dilutions. Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
Fiber optic temperature control with saphire thermowell, EPS pressure, and standard Teflon coated ring.
Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
Fiber optic temperature control with saphire thermowell, EPS pressure, and standard Teflon coated ring. Saber más
The 6 L Waste Option for Liberty Blue allows for the use of a larger waste container, increasing the scale and number of peptides that can be run before the waste container needs to be emptied. Saber más
The iPrep vessel is a high pressure, high sample weight, contactless monitored, high temperature vessel for use with MARS 6 with iWave. This vessel is well suited for digestion of difficult matrices such as waste oils, APIs with multiple aromatic rings, and geological samples. This vessel is also a great option when digesting 1 g or larger samples due to ppt detection limit needs.
The iPrep vessel is a high pressure, high sample weight, contactless monitored, high temperature vessel for use with MARS 6 with iWave. This vessel is well suited for digestion of difficult matrices such as waste oils, APIs with multiple aromatic rings, and geological samples. This vessel is also a great option when digesting 1 g or larger samples due to ppt detection limit needs.
Q-Cups are coated aluminum sample holders for the EDGE Extraction System. Q-Cups consist of a cylinder piece which holds the sample, and a threaded bottom piece which holds the Q-Disc filter. This kit includes 12 Q-Cups, which is the maximum number of samples that can be extracted in a run. For efficiency, it's recommended to have two sets (24 Q-Cups) and two Glass Vial Racks. This would allow one set to be ran in an EDGE, while another set is being prepared.
The iPrep vessel is a high pressure, high sample weight, contactless monitored, high temperature vessel for use with MARS 6 with iWave. This vessel is well suited for digestion of difficult matrices such as waste oils, APIs with multiple aromatic rings, and geological samples. This vessel is also a great option when digesting 1 g or larger samples due to ppt detection limit needs.
The iPrep vessel is a high pressure, high sample weight, contactless monitored, high temperature vessel for use with MARS 6 with iWave. This vessel is well suited for digestion of difficult matrices such as waste oils, APIs with multiple aromatic rings, and geological samples. This vessel is also a great option when digesting 1 g or larger samples due to ppt detection limit needs.
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The C1 discs are thin 2.5 µm cellulose filters recommended for extraction applications of dry samples. These discs are suitable for GC or Gravimetric analysis.
Glass vials to collect the extract placed in the rack for the EDGE Extraction system. These glass collection vials are clear, 40 mL, pre-sterilized and capped.
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The C4 discs are thin 11 µm cellulose filters recommended for extraction applications of dry or wet samples. These discs are suitable for GC or Gravimetric analysis.
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The M1 discs are thin 0.25 µm membrane filters recommended for extraction applications of dry samples. These discs are suitable for LC, GC or Gravimetric analysis.
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The C3 discs are thin 7 µm cellulose filters recommended for extraction applications of dry samples. These discs are suitable for GC or Gravimetric analysis.
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The C7 discs are thin 20 µm cellulose filters recommended for extraction applications of dry or wet samples. These discs are suitable for GC or Gravimetric analysis.
Glass vials to collect the extract placed in the rack for the EDGE Extraction system. These glass collection vials are graduated, 40 mL, pre-sterilized and capped.
Glass vials to collect the extract placed in the rack for the EDGE Extraction system. These glass collection vials are amber, 40 mL, pre-sterilized and capped.
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
Fiber optic temperature only control with saphire thermowell and standard Teflon coated ring. Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
Fiber optic temperature only control with saphire thermowell and standard Teflon coated ring.
Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
iWave temperature control and standard Teflon coated ring.
Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
iWave temperature control and standard Teflon coated ring.
Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
Fiber optic temperature control with saphire thermowell, EPS pressure, and premium ring.
Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
Fiber optic temperature control with saphire thermowell, EPS pressure, and premium ring.
Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
Fiber optic temperature only control with saphire thermowell and Premium ring.
Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
Fiber optic temperature only control with saphire thermowell and Premium ring.
Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
iWave temperature control and premium ring.
Saber más
Rugged, frame style vessels which are perfect for preparing difficult to digest organic materials such as oils and polymers as well as inorganic matrices such as ceramics and inorganic oxides.
iWave temperature control and premium ring.
Saber más
Glass vials to collect the extract placed in the rack for the EDGE Extraction system. These glass vials collection are clear, 60 mL, pre-sterilized and capped.
Glass vials to collect the extract placed in the rack for the EDGE Extraction system. These glass vials collection are amber, 60 mL, pre-sterilized and capped.
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The M2 discs are thin 0.25 µm membrane filters recommended for extraction applications of wet or dry samples. These discs are suitable for LC, GC or Gravimetric analysis. The C9 discs must be used underneath the M2 discs to provide structural support during extraction.
Q-Screens are inserted on top of the sample within the Q-Cup Sample Holder for the EDGE Extraction System. A tool is used to insert the reusable stainless steel screens to keep the sample firmly packed within the Q-Cup Sample Holder.
Q-Shields are applied to the top of the glass collection vials for the EDGE Extraction System. The disposable aluminum shields help to eliminate splashing and minimize evaporation of the extract. The collection vial cap can be used as a tool to firmly apply shields.
The Waste Bottle Assembly collects the waste for the 40 mL EDGE Extraction system. The 2 L bottle and cap equipped with a level sensor is connected to EDGE Extraction system by vent line tubing, drain line tubing and level sensor connector.
Q-Matrix Hydra, a polymer super absorbent, is used within the Q-Cup Sample Holder to aid in the removal of water from the sample for the EDGE Extraction System.
Transform your Phoenix BLACK into a workstation for automatic calculation, storage and transfer of results. This will assist you in complying with CFR 11 Part 21, ISO and other QC requirements.
For use in countries with 208-240V and 50/60HZ power supply. Saber más
This vapor scrubbing system can safely remove harmful fumes from the furnace cavity and neutralize any residual acid exhausted (sulfur dioxide and nitric acid). The configuration meets ISO 14000 regulations and all requirements for USP 281 (ROI) & USP 733 (LOI). The sulfated ash system can be disconnected in less than five minutes without the use of tools. The quartz furnace ceiling assures sample purity. USB data output provides CFR 21 part 11 compliance for output of data, method details and date of completion. Saber más
This vapor scrubbing system can safely remove harmful fumes from the furnace cavity and neutralize any residual acid exhausted (sulfur dioxide and nitric acid). The configuration meets ISO 14000 regulations and all requirements for USP 281 (ROI) & USP 733 (LOI). The sulfated ash system can be disconnected in less than five minutes without the use of tools. The quartz furnace ceiling assures sample purity. USB data output provides CFR 21 part 11 compliance for output of data, method details and date of completion. Saber más
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The C2 discs are thin 5 µm cellulose filters recommended for extraction applications of dry or wet samples. These discs are suitable for LC, GC or Gravimetric analysis.
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The G0 discs are thin 0.3 µm glass fiber filters recommended for extraction applications of dry or wet samples. These discs are suitable for LC, GC or Gravimetric analysis. When using G0 a Q-Support must also be used.
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The D2 discs are 1 µm polypropylene depth filters that can be used for PFAS extraction.
Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE Extraction System. The S1 discs are a stack of C9 + G1 + C9 Q-Disc recommended for all applications.
The Waste Bottle Assembly collects the waste for the 60 mL EDGE Extraction system. The 2 L bottle and cap equipped with a level sensor is connected to EDGE Extraction system by vent line tubing, drain line tubing and level sensor connector. Saber más
Kit for injection valve maintenance; includes normal wear parts, and tools for disassembly/reassembly. Part of annual preventative maintenance. Saber más
Flow cell for semi-prep to prep applications (low to medium sample loading). Stainless steel construction, 2 uL volume, 300 bar pressure limit Saber más
Back-pressure regulator assembly, including holder, replaceable cartridge, fittings and ferrules. Installed after the detector to prevent bubble formation in the flow cell. Saber más
Analytical 120 g capacity balance with 0.1 mg sensitivity. Includes appropriate cable to connect the balance directly to any Phoenix BLACK system for automatic results. Saber más
The HT12 option for the Liberty Blue and Liberty Prime provides automation for up to 12 peptide reactions. New reactions can be added and programmed at any time, even while another sample is running. Saber más
The HT24 option provides automated synthesis of up to 24 peptides. The HT24 requires the HT12 and allows for 12 more peptides to be added to a queue (24 total). The HT24 is recommended only for the Liberty PRIME 2.0 system. Saber más
Q-Screens are inserted on top of the sample within the Q-Cup Sample Holder for the EDGE Extraction System. A tool is used to insert the reusable stainless steel screens to keep the sample firmly packed within the Q-Cup Sample Holder.
Turntable designed to hold 40 standard 50 mL centrifuge tubes with cap. The HT-50 is designed for the extraction of PFAS from solid samples using IR temperature control. Saber más
PFAS Q-Discs are filters that are inserted into a Q-Cup Sample Holder for the EDGE PFAS Extraction System. These discs are tested to not contain PFAS and recommended for all sample types.