Q-Inserts

INTEC Technology: Rethinking PFAS Sample Preparation
INTEC Technology™ - Integrated Extraction and Cleanup – combines the cleanup step with the extraction process in a single step, direct to analysis in under 15 minutes. INTEC Technology isn't simply a faster extraction—it fundamentally simplifies the PFAS sample-preparation workflow by integrating cleanup where it belongs: directly into the extraction process.

Meets

  • EPA 1633A
  • ASTM D8535
  • ASTM D7968-23

Effective on

  • Long chain perfluoroalkyl acids
  • Fluorotelomer sulfonates
  • Fluorotelomer carboxylic acids
  • Sulfonamides
  • Sulfonamidoacetic acids
  • And more

INTEC Technology

Integrated Extraction and Cleanup

By integrating targeted cleanup sorbents directly into the Q-Insert™, INTEC Technology removes the need for a separate post-extraction cleanup process, streamlining the overall sample prep. This innovative approach minimizes hands-on processing, reduces solvent transfers and sample handling, and helps eliminate opportunities for contamination and variability— delivering a faster, simpler, and more consistent path from sample to result.


Representative recovery of PFAS compounds, well within acceptable performance criteria.
Highly Effective

Clean extracts without the extra steps

Extracts prepared using Q-Inserts delivered analytical results consistent with standard methodology for target analytes, with recoveries that were well within performance criteria. The streamlined workflow achieves these results without the need for a separate cleanup step. It simplifies sample preparation, reduces hands-on time, and helps labs move from sample to results more efficiently while maintaining confidence in the data.
Simple to Use

No additional cleanup processing required

Place Q-Insert into a Q-Cup® INTEC, add the sample, and place into an EDGE PFAS™ system. Upon completed extraction, the filtered and cleaned extract can be taken directly to analysis: no additional steps required.*
  1. Q-Cup Cylinder
  2. Q-Insert
  3. Threaded Bottom

* May vary depending on target concentration and method sensitivity.

Workflow

Integrated Extraction and Cleanup

Step 1

Assemble and Add Sample
Step 2

Place in unit and press play
Step 3

Analyze